Founded in 2024 as a spin-off from the established MeKo Manufacturing e.K., MeKo MedLab GmbH specializes in quality testing of high-precision medical devices – with a particular focus on endovascular prostheses and stents, guidewires, balloon catheters, and other minimally invasive components.
Our mission is to set the highest standards in the analysis and validation of medical devices. With state-of-the-art methods and extensive material expertise, we provide reliable testing services, such as mechanical property evaluations – including metal hardness testing, a central method with wide application.
Precision in testing and reliability in results are our top priorities. This allows us to support our customers in demonstrating the quality and safety of their products – and in sustainably strengthening trust in modern medical technology.
Your satisfaction is our commitment. We look forward to working with you – and to contributing together to the safe and dependable use of innovative medical devices.
















Ensures that the dimensions of catheters and implants meet specified requirements. High-precision instruments are used to determine parameters such as length, diameter, and wall thickness.
Determines the pressure at which a balloon catheter fails. Statistical analysis ensures with 95% confidence that 99.9% of the balloons will not burst at or below the specified RBP.
Measures the time required for a balloon to deflate after inflation. This test is essential for assessing balloon performance during surgery.
Evaluates the durability of balloons under repeated inflation and deflation cycles to ensure they withstand mechanical stress during clinical use.
Determines the volume at which a balloon fails under pressure to define the product’s safety limits.
Assessment of the dogboning phenomenon at the balloon ends during expansion, quantifying the relative overextension compared to the nominal stent diameter.
Analyzes the elastic behavior of stents after expansion. This test measures the degree of recoil after load removal to ensure the stent keeps the vessel open.
Evaluates the physical and mechanical properties of stents, including parameters like length, diameter, and material properties to ensure compliance with standards.
Measures the radial force exerted by a stent to keep a vessel open, assessing its ability to counteract natural vessel pressure.
Measures the ability of a stent to resist deformation under external compression.
Determination of the relationship between the prosthesis diameter and the balloon inflation pressure for balloonexpandable endovascular prostheses.
Long-term mechanical testing of stents under cyclic loads to assess fatigue resistance and durability throughout the expected lifespan.
Evaluates a stent’s resistance to repeated axial loads caused by vessel motion and pulsations within the body.
Assesses the stent’s ability to maintain structural integrity under repeated compressive loads in physiological conditions.
Determines the hardness of metallic materials by pressing a pyramid-shaped diamond into the surface under a specific load. The lengths of the diagonals of the indention is measured to calculate the hardness.
Used for measuring microhardness, especially for thin layers or delicate structures. A diamond indenter with an asymmetrical shape is pressed into the surface of a material under a specific load and the lengths of the indentation is measured.

07/16/2025
The excellent result confirms our strong technical expertise and our compliance with relevant standards in the execution of mechanical testing procedures. It reinforces our ongoing commitment to quality and reliability in the evaluation of material properties. What does this mean for our customers? You benefit from externally validated testing quality, precise measurement results, and a high level of confidence—even in demanding testing scenarios. Successfully completing this proficiency test is yet another proof of MeKo MedLab’s dedication to delivering excellence in materials testing.
Learn more
07/16/2025
To commission the system, a two-person expert team from the UK conducted an in-depth training session with the future users at MeKo MedLab. In parallel, a technician from Germany calibrated all 16 load cells to ensure precise and reliable measurements. Initial prototypes for customized sample holders were also tested successfully during the setup phase. Greater Efficiency and Flexibility for Our Customers The new fatigue tester allows for parallel lifetime simulations under realistic loading conditions. This significantly shortens development timelines and supports product approval processes. For MeKo MedLab customers, this means faster results, deeper testing insights, and even greater confidence in product validation. With this investment, MeKo MedLab strengthens its role as a reliable partner for precise, standards-compliant, and application-oriented component and materials testing for the medical device industry.